Inclusive® Custom Implant Abutments

Dental Lab Product Home  Product   Dental Lab Technical Information  Technical   Dental Lab Photos  Photos   Dental Lab Studies  Studies   Dental Lab Video  Video  
 
  • PDF Documents
  • Tech Notes
  • Indications
  • Preparation
  • Cementation
  • Working Time
TECHNICAL NOTES
INDICATIONS / CONTRAINDICATIONS
Indicated for missing teeth to provide a natural looking emergence profile that ensures ideal soft tissue contours and abutment heights in the anterior or posterior region. Titanium abutments are commonly used in all regions of the mouth due to their strength. Zirconia abutments are used for the best possible esthetics; they are commonly used in the anterior and combined with all-ceramic or zirconia restorations.
PREPARATION
Use manufacturer's tooling to remove healing cap. For multiple units, start in the posterior and work toward anterior. Then, use manufacturer's tooling to place transfer coping. Ensure components are fully engaged before tightening screw. Take an X-ray to verify proper seating of components. Next, ensure transfer coping does not hit tray. Use heavy body polyvinylsiloxane impression material. Record impression. Finally, when impression tray is removed, the transfer coping stays in the mouth. Remove transfer coping and replace healing cap. For multiple units, start in anterior and work toward posterior. Check fit of impression coping into impression. Send to lab.
CEMENTATION
Seat abutment. Torque screw into place per manufacturer's recommendations. Next, use composite to fill over the implant screw. Cement restoration over implant with a resin-reinforced ionomer (i.e., RelyX, 3M ESPE).
WORKING TIME
8 Days In Lab
2 Days In Lab when file submitted digitally using 3Shape AbutmentDesigner file
Rush Cases : All rush cases must be prescheduled by calling 800-944-7874 before the case is shipped. Time of pickup and delivery may affect turnaround time.
 
 
   