TECHNICAL NOTES
Sterility –

Inclusive Mini implants are shipped sterile. They are for single use only, prior to the expiration date. Do not use implants if the packaging has been compromised or previously opened. Steam sterilize the surgical tray for twenty (20) minutes at 132°C/270°F minimum.

Quality —

Inclusive Mini Implants are manufactured in accordance with the strictest quality standards throughout their production process, from materials and design to final product and packaging. We ensure tight tolerances, precision machining, state-of-the-art processing and cleaning, and extensive validation testing–from fatigue strength assessment to packaging integrity analysis.
Treatment Planning–

The implant site should be inspected for adequate bone by radiographs, palpations, and visual examination. Determine the location of nerves and other vital structures and their proximity to the implant site before any drilling. Prior to surgery, ensure that the needed components, instruments and help materials are complete, functional and available in the correct amounts. Treatment of children is not recommended until growth is finished and epiphyseal closure has occurred.

Inclusive Mini Implants should always be used in sufficient quantity to prevent excessive stress on the implants—at least one pair in all cases.

Typically, Type I bone would indicate the use of 2.2 mm diameter Inclusive Mini Implants. Type II/Type III bone would indicate the use of 2.5 mm/3.0 mm diameter Inclusive Mini Implants. Type IV bone contraindicates the use of Inclusive Mini Implants.
Insertion Protocol and Immediate Loading–

The insertion protocol for Inclusive Mini Implants is considered minimally invasive, and should be strictly adhered to. Using the correct insertion protocol will allow Inclusive Mini Implants to be immediately loaded after placement, provided primary stability and appropriate occlusal loading are assured.
Surgical Procedure Precautions–

Minimizing tissue damage is crucial to successful implant osseointegration. Care should be taken to eliminate sources of infection, contaminants, surgical and thermal trauma. All drilling procedures should be performed at 1200 RPM or less under continual, copious irrigation. All surgical instruments used must be in good condition, and should be used carefully to avoid damage to implants or other components. Implants should be placed with sufficient stability (35 Ncm recommended); however, insertion torque greater than 45 Ncm may result in implant fracture, or fracture or necrosis of the implant site. Since implant components and their instruments are very small, precautions should be taken to ensure that they are not swallowed or aspirated by the patient.
Prosthetic Procedure Precautions–

All components that are used intra-orally should be secured to prevent aspiration or swallowing. Distribution of stress is an important consideration. Care should be taken to avoid excessive loads significantly transverse to the implant axes.
INDICATIONS / CONTRAINDICATIONS
Inclusive Mini Implants are self-tapping threaded titanium screws indicated for long-term applications. Inclusive Mini Implants may also be used for provisional applications. These devices will allow immediate loading and long-term stabilization of dentures and provisional stabilization of dentures while standard implants heal. The implants are to be used for immediate loading only in the presence of primary stability and appropriate occlusal loading.

Patients should be evaluated before the time of surgery for factors that put them at risk from the implant placement procedure, or that may affect healing of bone or surrounding soft tissue. Implant placement in patients medically unfit for oral surgical procedures is contraindicated. Patients with systemic, localized or pharmaceutical treatment factors that compromise their ability to heal should be carefully evaluated. Do not place Inclusive Mini Implants if there is not adequate bone width or height to contain the implant.
PREPARATION
 
CEMENTATION
 
WORKING TIME
5 Days In Lab
Rush Cases : All rush cases must be prescheduled by calling 800-944-7874 before the case is shipped. Time of pickup and delivery may affect turnaround time.
CODES
 
 
   
Policies & Warranty   USA Flag
 
 
    Visit the aveoTSD website Visit the BruxZir website Visit the Inclusive Dental Implants website Glidewell Dental Lab Mobile Visit Glidewell Dental Lab on Facebook Visit Glidewell Dental Lab on Twitter Visit Glidewell Dental Lab on iTunes Visit Glidewell Dental Lab on YouTube
aveoTSD BruxZir Inclusive FastScan H/S Splint Facebook Twitter iTunes YouTube