Bite Splints
|
-
Figure #1
Place the upper and lower models securely into the Occluform attachment and tighten.
-
Figure #2
Mount the opposing model using the patient's open construction bite, as shown.
-
Figure #3
Fill the model container with granules. Be sure to fill in any open spaces underneath the model.
-
Figure #4
After the heating cycle is finished, place the disc over the model to activate the vacuum.
-
Figure #5
Place a sheet over the model to prevent sticking. Close the Occluform to imprint a flat bite plane.
-
Figure #6
Remove the disc ring and lift both the disc frame and model container out of the unit.
-
Figure #7
Using a fissure bur, rough cut the splint out of the disc. Be sure to retain the natural undercut.
-
Figure #8
A crosscut carbide bur and Lisko-S disc are used to contour, smooth and polish cut areas.